Ethylene Oxide Chemical Storage Specifications

Compliant storage and rental solutions for Ethylene Oxide (C2H4O). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

About Ethylene Oxide

a flammable toxic gas used as an intermediate and fumigant.

Structured hazard data

Hazard class
FLAMMABLE GASES - Category 1
Storage category
Flammable Storage
Flammable
Yes
Flash point
Closed cup: -29°C (-20.2°F) Open cup: -29.15°C (-20.5°F)
Storage temperature
Avoid temperates above 38 ºC and do not exceed temperatures of 52 ºC
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Ethylene Oxide is not compatible with AMMONIA; METALS (such as POTASSIUM, SILVER and MERCURY); ALCOHOLS; MERCAPTANS; CYANIDES; AMINES; and HALOGENATED HYDROCARBONS (such as METHYLENE CHLORIDE and TRICHLOROETHYLENE).

GASES UNDER PRESSURE - Liquefied gas ACUTE TOXICITY (inhalation) - Category 3 SKIN IRRITATION - Category 2 EYE IRRITATION - Category 2A GERM CELL MUTAGENICITY - Category 1 CARCINOGENICITY - Category 1 SPECIFIC TARGET ORGA

Fire Suppression System

Dry Chemical fire suppression is recommended for Ethylene Oxide

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Ethylene Oxide (C2H4O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: alcohol foam, carbon dioxide, dry chemical or water spray, fog, or foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Ethylene Oxide should account for its listed hazards (FLAMMABLE GASES - Category 1), climate control needs (Avoid temperates above 38 ºC and do not exceed temperatures of 52 ºC), and segregation requirements. Ethylene Oxide is not compatible with AMMONIA; METALS (such as POTASSIUM, SILVER and MERCURY); ALCOHOLS; MERCAPTANS; CYANIDES; AMINES; and HALOGENATED HYDROCARBONS (such as METHYLENE CHLORIDE and TRICHLOROETHYLENE).

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: Colorless gas. Melting point: -111.7°C (-169.1°F). Boiling point: 10.7°C (51.3°F)

Matched to this chemical

Recommended storage solutions for Ethylene Oxide

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Ethylene Oxide be stored?

Store Ethylene Oxide in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (FLAMMABLE GASES - Category 1). Climate range guidance: Avoid temperates above 38 ºC and do not exceed temperatures of 52 ºC. Compatibility notes: Ethylene Oxide is not compatible with AMMONIA; METALS (such as POTASSIUM, SILVER and MERCURY); ALCOHOLS; MERCAPTANS; CYANIDES; AMINES; and HALOGENATED HYDROCARBONS (such as METHYLENE CHLORIDE and TRICHLOROETHYLENE). US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Ethylene Oxide flammable?

Yes — Ethylene Oxide is flagged as a flammable hazard in this database (Yes). Flash point: Closed cup: -29°C (-20.2°F) Open cup: -29.15°C (-20.5°F). Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Ethylene Oxide?

Ethylene Oxide is listed as: FLAMMABLE GASES - Category 1. GASES UNDER PRESSURE - Liquefied gas ACUTE TOXICITY (inhalation) - Category 3 SKIN IRRITATION - Category 2 EYE IRRITATION - Category 2A GERM CELL MUTAGENICITY - Category 1 CARCINOGENICITY - Category 1 SPECIFIC TARGET ORGA

What fire suppression is recommended for Ethylene Oxide?

Dry Chemical fire suppression is generally recommended for Ethylene Oxide (C2H4O). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Ethylene Oxide storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Ethylene Oxide. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.